SJD-100KVA
Overview:
Electrical equipment is designed to accept a wide range of input voltages about its nominal design centre. However, if the actual supply is higher than necessary the equipment will consume more power than needed and in many cases, equipment life is reduced, effectively in creasing the cost of ownership.
A 230V linear appliance operated at 240V will consume approximately 9% more energy than necessary. A voltage reduction within statutory limits can produce up to 25%(subject to load) reduction in energy consumption and in addition will extend the life of many types of electrical equipments.
By reducing supply voltages to a controlled, site adjustable level, our Voltage Optimization Unit(VOU) allows equipment to operate at optimum efficiency. The result is lower overall running and ownership costs and reduced carbon footprint each kWh of electrical energy saved is equivalent to 0.537kg of CO2.
Features:
During the working period of electric illumination equipments or appliances, the energy-wasting factors like unbalance load, harmonics, and reactive power could lead to great electricity losses and unnecessary rise in power consumption, low efficiency, and higher maintenance costs. Also, the lifespan of these equipments will be shortened because of those factors.
As a power solution provider, we have taken our own responsility to research and developed a special kind of intelligent power conditioner for illumination system, such as for gas discharge lamps.
Benefits:
- Energy saving of up to 25%
- Fast return of investment(ROI) time
- Prolonged equipment life span
- High operational efficiency
- Adjustable configurations based on site requirements
- GPRS and Wireless Energy Monitors for real-time energy monitoring
- Protects equipment against failures due to over or under voltage
- Internal no-break bypass allowing no power interruption during maintenance
- Single and three phase up to 5000KVA
Input Voltage |
Phase to neutral: 230V±15% (195V~265V) adjustable |
Output Voltage |
Phase to neutral: 220V adjustable |
Output Accuracy |
±1.5% |
Supply Frequency |
50/60Hz |
Voltage Regulation Mode |
Independent phase regulation |
Insulation Class |
H class |
Duty Type |
Continuous |
Cooling Type |
Natural Air(AN)/Forced Air(AF) |
Efficiency |
>98% at full load |
Protection Class |
IP20(indoor), outdoor on request |
Electrical Safety |
CE equivalent |
Operational Temperature |
-20 °C to +45 °C |
Relative Humidity |
<90% |
GPRS |
Remote control and monitoring the VO unit parameters |
Master Controller |
Set output voltages 225V, 220V and 215V by manual |
|