Static Var Generators (SVGs) Single Phase /Three Phase

Product Details
Customization: Available
Certification: ISO9001
Protection: Corrosion Resistance
Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2008
Export Year
2008-08-08
OEM/ODM Availability
Yes
  • Static Var Generators (SVGs) Single Phase /Three Phase
  • Static Var Generators (SVGs) Single Phase /Three Phase
  • Static Var Generators (SVGs) Single Phase /Three Phase
  • Static Var Generators (SVGs) Single Phase /Three Phase
  • Static Var Generators (SVGs) Single Phase /Three Phase
  • Static Var Generators (SVGs) Single Phase /Three Phase
Find Similar Products

Basic Info.

Model NO.
SVG
Installation
Vertical
Housing
UPR
Transport Package
Wooden Package
Trademark
OEM/ODM
Origin
China
HS Code
8504401990
Production Capacity
500 PCS/Year

Product Description

Introduction to Modular Power Quality Regulators
Our modular power quality products include: Static Var Generators (SVGs), Advanced SVGs (ASVGs) and Active Power Filters (APFs). They have features such as high power density, enhanced reliability, optimized performance, high utilization and unique designs. For use in different application scenarios, there are three way to install them: drawer style, wall-mounted style and upright style.

Main Features of Modular Power Quality Regulators

Our modular power quality regulators:
  • Are compact, with a maximum size of only 0.05m³, have a high power density, and apply to a variety of scenarios. In practice, they are more applicable to places where limited space poses a stringent requirement on the ground they could cover, as well as power distribution upgrading projects.
  • Employ the same design concepts as industry-grade products, and therefore, highly adaptable to the environment.
  • Furnish the module control layer with a board compartment that reaches a dust-proof rating of IP6X and has withstood the nationally recognized third-party lab testing.
  • Apply an interleaving control manner at the output end. This reduces at least 40% of global ripple current.
  • Support a dynamic response at ms level, with a global response time less than 2ms. Therefore, they can accurately track how transient current changes in the power grid and prevent over-compensation and under-compensation.
  • Employ an industry-leading redundant design based on Insulated Gate Bipolar Transistors (IGBTs). As a result, failure in one line will not affect the proper running of the system.
  • Allow devices to detach from the power grid in case of a breakdown, with no port capacitors remain connected to the grid, thus preventing any negative impact on the harmonic oscillator and capacitive reactive power of the grid.
  • Support a CT connecting at the power supply side or the load side, which you can adjust according to on-site requirements.
  • Have a fast and thorough fault self-diagnosis function, which can be intelligently adjusted based on actual operating conditions and states.
  • Make it easier to maintain by using separately removable parts such as bus capacitor and fan.
  • Support a smart algorithm, which automatically adjusts the compensation proportion based on real-time changes in reactive current and harmonic current, and also supports flexibly setting a compensation goal, in order to optimize your business objective.
  • Support smart sleep in which two parallel systems apply a polling mechanism to allocate an average worktime for each module under a light load condition, thus extending module lifetime.
  • Have passed the CE certification and conform to EN 62477-1: 2012+A11-2014+A1-2017 standard;
Each of our products has the following compensation feature:
  • An APF supports a wider range of compensation, that is, instantaneous 2nd - 51st harmonic compensation;
  • An ASVG supports 2nd - 23rd harmonic compensation. You can set harmonic compensation capacity and reactive compensation capacity globally.
  • An SVG supports global, instantaneous compensation for inductive reactive power and capacitive reactive power, and meanwhile, solves the three phase unbalance problem.
Enhanced Reliability & Performance
Industry-first dust-proof module at the control layer: The control section is separated from the power section. The control layer applies a fully closed dust-proof design, with no vent holes at two sides, front and back, thus obtaining an excellent sealing; while at the air cooling layer, critical power units are cooled by the power layer, thus achieving a superior device cooling performance. In addition, the control layer reaches a protection class of IP6X and has withstood the third-party lab testing. This isolates the control section from being polluted by the outer world. Besides, we employ an industry-grade hardware design, which further improves security and reliability.

Static Var Generators (SVGs) Single Phase /Three Phase



 
Static Var Generators (SVGs) Single Phase /Three Phase
Static Var Generators (SVGs) Single Phase /Three Phase
                         At the dust-proof certification test                                                                After the dust-proof certification test
 
Use of a separate control scheme for each IGBT, which is much more reliable because: each IGBT is equipped with a set of drives and a hall element, and in the case that the IGBT on one side fails, the device still could offer 50% of the rated output capacity.
Static Var Generators (SVGs) Single Phase /Three Phase

Providing a soft-start relay and resistor between a filter capacitor and the power grid, to ensure that when a device fails, the filter capacitor breaks away from the grid, without posing any secondary impact on the grid.
Static Var Generators (SVGs) Single Phase /Three Phase
  • Quicker response: Use of a Second-Order Generalized Integration (SOGI) algorithm achieves a global response time of less than 2ms, making it possible to accurately tract how harmonic content and reactive content change in the power grid and prevent over-compensation and under-compensation.
Static Var Generators (SVGs) Single Phase /Three Phase
Static Var Generators (SVGs) Single Phase /Three Phase

In the response test of a sudden load rise, the oscillometer record shows that the global response time on the display is 1.36ms.
In the response test of a sudden load drop, the oscillometer record shows that the global response time on the display is 1.96ms.
  • Advanced harmonic suppression technology: Quickly suppresses the harmonic state in less than 1s after a device detects that harmonic current is inevitable in the power grid, making sure that the device will not be turned off entirely so that it can go on performing compensation for the system.
Static Var Generators (SVGs) Single Phase /Three Phase
  • Low ripple output: An interleaving-based low-ripple control technology achieves a smooth waveform even for a 60th harmonic output.
Static Var Generators (SVGs) Single Phase /Three Phase

Modular APF/ASVG/SVG Model

Static Var Generators (SVGs) Single Phase /Three Phase
ASVG/SVG Model for Quick Selection
Transformer Capacity
(kVA)
CosФ
<0.5 0.5 - 0.6 0.6 - 0.7 0.7 - 0.8 0.8 - 0.9
1000 550kvar 550kvar 450kvar 350kvar 200kvar
1250 600kvar 600kvar 550kvar 450kvar 235kvar
1600 800kvar 800kvar 700kvar 550kvar 300kvar
Remarks 1. For use in harsh environment, we recommend industry-specific cabinet-style products;
2. For use in scenarios where harmonic current and reactive current are excessively large, configure our products based on actual calculation or in-site test data.

Modular SVG Parameters
Model SVG 15kvar SVG 25kvar SVG 35kvar SVG 50kvar SVG 70kvar SVG100kvar
System Parameters
Grid voltage 400V (-40% - +20%)
Grid frequency 50Hz/60Hz (±10%)
Pieces to be integrated No limit
Efficiency Up to 98%
Wiring mode 3-phase 3-wire/3-phase 4-wire
Heat loss <2%
CT 150/5 - 10000/5
Connection mode Connect from the back/top
Air in/out Front to back/Top to bottom
Performance Indicators
Global response time <2ms
Power factor Adjustable from -1 - +1
Cooling mode Intelligent air cooling
Noise <58dB
Fixing mode Drawer style, wall-mounted style and upright style
Dimension
(W*D*H mm)
Drawer style: 442*485*90
Wall-mounted: 442*90*485
Drawer style: 500*590*150
Wall-mounted: 505*175*640
Upright: 170*525*590
Drawer style: 500*590*170
Wall-mounted: 505*195*640
Upright: 170*525*590
Net weight 20kg 35kg 45kg
Environment Parameters
Altitude ≤2000m, 2000m - 4000m de-rating
Operating temperature -10ºC - +50ºC (>40ºC, use upon de-rating)
Relative humidity 5% - 95%, non-condensing



 

 