Customization: | Available |
---|---|
Current Type: | AC |
Phase: | Three Phase |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Our DVR is connected in parallel within a power grid system. When the grid voltage is normal, an SCR on the power source side is connected, and the power grid can directly feed various devices. At the same time, a bi-directional inverter is in a standby state and monitors in real time how the grid voltage fluctuates. | |
At the instant when an unexpected voltage fluctuation is detected, our DVR switches backend devices to be powered by a supercapacitor or other energy storage units. This ensures proper running of those backend devices will not be affected. | |
When the grid voltage goes back to normal, and our DVR determines that the power supplied meets related standards, it switches the backend devices to be powered by the power grid, and simultaneously charges the backup energy storage units over the bi-directional inverter. |
Series | DVR50 -150kVA | DVR200 - 350kVA | DVR400 - 450kVA | DVR500kVA or above |
System Parameters | ||||
Rated voltage | 208V, 220V, 380V, 400V, 415V, 460V, 480V | |||
Rated capacity | 50kVA, 75kVA, 100kVA, 150kVA | 200kVA, 250kVA, 300kVA, 350kVA | 400kVA, 450kVA | 500kVA or above |
Rated frequency | 50Hz/60Hz, ±5Hz | |||
Voltage range | -40% - +20% (You can set this value) | |||
DC voltage | 180 - 750Vdc (The minimum value can be adjusted as needed.) | |||
Pieces to be integrated | 8 | |||
Global efficiency | ≥99% | |||
Wiring mode | 3-phase 3-wire; 3-phase 4-wire | |||
Connection mode | Connect lines from both the top and the bottom | |||
Air in/out | Air in from the bottom and out through the top | |||
Performance Indicators | ||||
Overall response time | <1ms | |||
Voltage precision | 1% | |||
Sag compensation capability | 100%; compensation cycle 3s; for a longer cycle, add a supercapacitor as needed. | |||
Overload capability | Overload 125%, lasts at least 10min; Overload 150%, lasts at least 1min | |||
Cooling mode | Air-cooled | |||
Noise | <68dB | |||
Fixing mode | Cabinet | |||
Dimensions (W*D*H mm) |
600*1000*2000 | Power cabinet: 600*1000*2000 Super-capacity cabinet: 600*1000*2000 |
Power cabinet: 600*1000*2000 Super-capacity cabinet: 800*1000*2000 |
For a capacity of 500kVA or above, you can adjust as needed. |
Environment Parameters | ||||
Altitude | ≤2000m, 2000m - 4000m (De-rating) | |||
Operating temperature | -10ºC - 40ºC | |||
Relative humidity | 5% - 95%, non-condensing |